Tramex Water Damage Restoration Inspector Kit - WDIK
Product Code: WDIKCOMPLETE MOISTURE METER KIT FOR WATER DAMAGE RESTORATION OF BUILDINGS AND BUILDING MATERIALS
WITH ACCOMPANYING BLUETOOTH APP
The Tramex WDIK is the complete kit for moisture content and relative humidity testing and monitoring of ambient conditions, concrete, wood, tiles, drywall, plaster and numerous building materials after water damage. Featuring the Tramex ME5 for dual-depth, non-invasive testing of moisture conditions in drywall, wood, plaster, brick, tiles, resilient flooring, laminates and roofing. The Tramex CMEX5 digital concrete moisture meter allows for quantitative moisture content measurement using Gravimetric testing as a baseline, comparative testing of concrete and ambient conditions measurement. The Tramex Feedback Datalogger gives live readings and time logs relative humidity, temperature and dew point in the environment and in materials and air spaces with the plug-in relative humidity probe. An infrared surface thermometer gives surface temperature and dew point conditions used in conjunction with the CMEX5 hygrometer. A heavy-duty pin-probe measures moisture content in wood or WME in other building materials. The Tramex Water Damage Restoration Inspection Kit comes with an extension handle in a protective heavy-duty carrying case with die-cut foam lining. Bluetooth connectivity to the Tramex Meters App allows for visualization of readings and data reporting to mobile devices, to GeoTag test results, create, save and share photos, reports and charts, as well as see your meter screen on your phone when extending to hard to reach places.
KIT CONTENTS
1 x Concrete Moisture Encounter X5 - CMEX5.
1 x Moisture Encounter 5 - ME5.
1 x Feedback Datalogger - DL-RHTX.
1 x Heavy-duty pin-type wood probe - HH14TP30
1 x 127mm short narrow Relative Humidity probe - RHP-SNW-B
1 x 200mm (pack of 2) insulated pins for in-depth penetration - SP200
1 x Calibration Check Salts - SAL75
1 x Infrared Thermometer - IRT2
1 x Extension Handle - E5-HBS
Free App available for Android and iOS (phone not included).
CONCRETE MOISTURE ENCOUNTER X5 - CMEX5 - MEASURING RANGE:
Depth of penetration in concrete: approx. 20mm
Moisture content for Concrete: 0 → 6.9 %
Comparative for Gypsum floor screed: 0 → 12
CM Equiv Anhydrite/Concrete: 0→2.7 / 0→4.3
Reference scale: 0 → 100
Relative Humidity (including with Hygro-i2 ® probe): 0 → 99%
Humidity accuracy: 0% to 99%RH +/- 2% @ 25°C
Moisture content for wood with wood pin probes: 5 → 30 %
MOISTURE ENCOUNTER 5 - ME5 - MEASURING RANGE:
Wood Moisture Content: 5 to 30%
Reference scale for building materials: 0 to 100
Depth of penetration:
Shallow signal: up to 10mm
Deep signal: up to 30mm
FEEDBACK DATALOGGER DL-RHTX MEASURING RANGE:
Memory: 100,000 data point entries (samples of Ambient RH and temperature; SurfaceTemperature)
Logging Rate: Logger interval adjustable between 5 minutes and 1 hour
Transmission Range: Up to 50m line-of-sight
Bluetooth: BLE Bluetooth Low Energy 4.2 compliant, Bluetooth 5 advertising
RELATIVE HUMIDITY SENSOR SPECIFICATIONS:
Range: 0 to 100% RH
Accuracy: ±1.5%RH Range 0% to 80%RH ±2.0%RH Range 80% to 99%RH (@ 77ºF (25ºC))
Resolution: 0.1% over the complete range
Drift: <0.25%RH per year
TEMPERATURE SENSOR SPECIFICATIONS:
Range: -40ºF to 257ºF (-40ºC to 125ºC)
Accuracy: ±0.1ºF Range 68ºF to 140ºF (±0.1 °C Range 20°C to 60°C)
Sensor Protection: PTFE Film protects sensor opening from water & dust
Drift: <0.04ºF (0.03ºC) per year
INFRARED THERMOMETER IRT2
Temperature range: -50 to 650 ºC
Distance to Spot ratio: D:S = 12:1
Display resolution: 0.1 ºF(0.1ºC) <1000 1ºC >1000
Accuracy for targets: Assumes ambient operating temperature of 73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC) ±4.5ºF(2.5ºC) 68ºF ~572ºF (20ºC ~300ºC) ±1.0% ±1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%
Repeatability: -58~68ºF (-50~20ºC) : ±2.3ºF(1.3ºC ) 68~1202ºF (20~650ºC): ±0.5% or ±0.9ºF (0.5ºC)
Response time: 150ms
Spectral response: 8~14um
Emissivity: Digitally adjustable from 0.10 to 1.0
Over range indication: LCD will show “----”
Polarity: Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: 0 to 50ºC
Storage temp.: –10 to 60ºC
Relative humidity: 10%~90%RH operating, <80%RH storage
Power supply: 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: “ CE ” Comply with EMC
SPECIFICATIONS OF KIT:
Size: 43.5cm x 36cm x 14cm
Weight: 3.9kg
Power: 5 x AA batteries, 1 x 9 volt PP3 battery